Hager VBE98101PSPD is a 3-row surface-mounted consumer unit for domestic and light commercial installations. Rated at 80A, 54 modules total capacity. Comes with overvoltage protection (SPD), single-phase inlet, and split-load configuration.

  • 54 modules across 3 rows
  • 80A main rated current
  • IP40 ingress protection, IK07 impact resistance
  • Surface mount, white polystyrene enclosure
  • Interlock plain white door
Specifications

Mounting Type

Surface mounted

Rated Current

80A

Number of Modules

54

Number of Rows

3

IP Rating

IP40

Impact Resistance

IK07

Height

600 mm

Width

370 mm

Depth

145 mm

Colour

Pure white (RAL 9010)

Material

Polystyrene (PS)

Overvoltage Protection

Yes (SPD)

Door

Interlock, plain white

What's included

1x SBR290 2P 100A Isolator Switch

1x CD285U 2P 100A RCCB

4x MBN120W - B20 6kA MCB 1M

1x MBN132W - B32 6kA MCB 1M

1x MBN110W - B10 6kA MCB 1M

2x ADA306G - B6 6kA RCBO 1M

Surge Protection

Hager Electrical Distribution

Circuit Overload & Short Circuit Protection

Hager MCBs provide reliable protection for individual circuits against overloads and short circuits. Available in Type B and Type C characteristics to suit both domestic and commercial installations, they are designed for straightforward DIN rail mounting inside Hager consumer units and distribution boards. Choose the correct amperage rating to match the circuit load — from lighting and sockets through to high-demand appliances.

Per-Circuit Earth Fault & Overcurrent Protection

Hager RCBOs combine the functions of an MCB and an RCD into a single compact module, providing both overcurrent protection and earth leakage detection on a per-circuit basis. Operating at 30mA sensitivity, they disconnect the circuit instantly if a potentially dangerous earth fault is detected — making them the preferred choice for 18th Edition compliant installations. Each RCBO occupies a single way, keeping your board neat and allowing faults to be isolated without disrupting other circuits.